45 Minute
45 Minute Fire Rating Doors
Ratings | Single Swing Door and Transom | Pair Regular or Double Egress |
Positive Pressure “S” Label | Yes* | Yes* |
Sizes: Positive Pressure shown |
4’x 9’ 4’x 9’ Door & Transom Max Transom = 4’x 3’4” |
4’x 9’ Regular 8’x 9’ Dbl Egress 8’x 8’ CVRE |
Protection Plates | 48”x 48” Note: 2 | 48”x 48” Note: 2 |
EPT | Yes Note: 2 | Yes Note: 2 |
Wire Chase | Yes | Yes |
Dutch Door | 4’ x9’ No Vision Panel |
N/A |
Maximum Vision Panel | 1,296 sq. in. 2,638 sq. in. Note: 1 |
1,296 sq. in. 2,638 sq. in. Note: 1 |
Maximum Louver Fusible Link | 24″ x 24″ | 24″ x 24″ each leaf |
Viewers | Up to 1” diameter | Up to 1” diameter |
Hinges | Per NFPA #80 Note: 7 |
Per NFPA #80 Note: 7 |
Locks | Cylindrical/ Unit/ Mortise | Cylindrical/ Unit/ Mortise |
Exit Devices | Listed rim, mortise or vertical rod | Listed rim, mortise or vertical rod |
Flush Bolts
Top/Bottom |
N/A | Listed surface manual or automatic flush bolts installed with 28 gauge liner |
Edge Guards | Yes, Note: 3 | Yes, Note: 3 |
Concealed Vertical Rod | Yes, 5″ channel may be required | Yes, 5″ channel may be required |
Concealed Closers | Yes, Note: 2 | Yes, Note: 2 |
Applied Moldings | Yes | Yes |
Automatic Door Bottoms | Yes, Note: 2 | Yes, Note: 2 |
Note:
(1) Special glass and stop required/max size 36”x80”.
(2) Special blocking required.
(3) Special edges required.
(4) Special glass and stop required.
(5) Special blocking required.
(6) No astragal required with special blocking.
(7) Special hinges and pivots require additional blocking.
(8) Contact factory for hardware options.
*Contact factory for maximum sizes and options for Neutral and Positive Pressure requirements.
Click here to download PDF version.
Vancouver Door Company, Puyallup WA.
1-800-999-3667