60-90 Minute
60-90 Minute Fire Rating Doors
Ratings | 60 Minute Single Swing Door and Transom |
60 Minute Pair Regular or Double Egress |
90 Minute Single Swing Door and Transom |
90 Minute Pair Regular or Double Egress |
Positive Pressure “S” Label | Yes* | Yes* | Yes* | Yes* |
Sizes: Positive Pressure shown |
4′ & x 9’ 4’x 9’ Door & Transom Max Transom = 4’x 3’4” |
4’x 9’ Regular 8’x 9’ Dbl Egress 8’x 9’ CVRE |
4’x 9’ 4’x 9’ Door & Transom Max Transom = 4’x 3’4” |
4’x 9’ Regular 8’x 8’ Dbl Egress 8’x 9’ CVRE |
Protection Plates | 48”x 48” Note: 2 | 48”x 48” Note: 2 | 48”x 48” Note: 2 | 48”x 48” Note: 2 |
EPT | Yes Note: 2 | Yes Note: 2 | Yes Note: 2 | Yes Note: 2 |
Wire Chase | Yes | Yes | Yes | Yes |
Dutch Door | N/A | N/A | N/A | N/A |
Maximum Vision Panel | 100 sq. in. 1015 sq. in. Note: 4 |
100 sq. in. 1015 sq. in. Note: 4 |
100 sq. in. 1015 sq. in. Note: 4 |
100 sq. in. 1015 sq. in. Note: 4 |
Maximum Louver Fusible Link | 24″ x 24″ | 24″ x 24″ each leaf | 24″ x 24″ | 24″ x 24″ each leaf |
Viewers | Up to 1″ diameter | Up to 1″ diameter | Up to 1″ diameter | Up to 1″ diameter |
Hinges | Per NFPA #80 Note: 7 |
Per NFPA #80 Note: 7 |
Per NFPA #80 Note: 7 |
Per NFPA #80 Note: 7 |
Locks | Cylindrical/ Unit/ Mortise | Cylindrical/ Unit/ Mortise | Cylindrical/ Unit/ Mortise | Cylindrical/ Unit/ Mortise |
Exit Devices | Listed rim, mortise or vertical rod | Listed rim, mortise or vertical rod | Listed rim, mortise or vertical rod | Listed rim, mortise or vertical rod |
Flush Bolts
Top/Bottom |
N/A | Listed surface manual or automatic flush bolts | N/A | Listed surface manual or automatic flush bolts |
Edge Guards | Yes, Note: 3 | Yes, Note: 3 | Yes, Note: 3 | Yes, Note: 3 |
Concealed Vertical Rod | Yes, 5″ channel may be required | Yes, 5″ channel may be required | Yes, 5″ channel may be required | Yes, 5″ channel may be required |
Concealed Closers | Yes, Note: 2 | Yes, Note: 2 | Yes, Note: 2 | Yes, Note: 2 |
Applied Moldings | Yes | Yes | Yes | Yes |
Automatic Door Bottoms | Yes, Note: 2 | Yes, Note: 2 | Yes, Note: 2 | Yes, Note: 2 |
Note:
(1) Special glass and stop required/max size 36″x80″.
(2) Special blocking required.
(3) Special edges required.
(4) Special glass and stop required.
(5) Special blocking required.
(6) No astragal required with special blocking.
(7) Special hinges and pivots require additional blocking.
(8) Contact factory for hardware options.
*Contact factory for maximum sizes and options for Neutral and Positive Pressure requirements.
Testing: Labeled fire doors have been tested in accordance with UL 10(B), CAN 4S 104(ULC-S104), NFPA 252 and UBC 7-2 fire door test standards.
Labeling: Testing, inspection and labeling is by Intertek Testing Services/Warnock Hersey, Inc. Vancouver Door Co. is listed to manufac- ture and machine fire rated wood doors. Labels are affixed to hinge edge at eye level, or on top rail if positive pressure.
Click here to download PDF version.